How Wearables Detect Sleep and Whether to Trust Sleep Stages

How sleep tracking uses movement and heart rate, what comparisons with lab polysomnography found, and how to read the data without anxiety.

For education. Use a qualified healthcare professional for diagnosis and treatment decisions. How we use sources.

A wearable cannot see your brain. Most consumer devices have an accelerometer, like a standard actigraph, and many also have a heart-rate sensor. The manufacturer’s proprietary algorithm turns these signals into “sleep,” “awake,” and sleep stages 1. In laboratory comparisons with polysomnography in healthy young people, devices reliably detected sleep (sensitivity of at least 0.93) but were much worse at identifying wakefulness during the night, and agreement on sleep stages was uneven. So weekly total sleep time is considerably more trustworthy than one night’s sleep-stage breakdown.

What exactly does a device measure?

The reference standard is polysomnography: a laboratory recording that includes electroencephalography, or brain activity. A consumer tracker does not do this. In Chinoy’s study, devices were compared with this standard and with actigraphy. The authors explain, using actigraphy as an example, that during awakenings people often barely move, so those periods can be counted as sleep 1.

Consumer sleep trackers come in three types: worn on the body, placed near the bed, and mobile apps 2. They use different signals and have different kinds of errors.

What lab comparisons found

In Chinoy’s study, 34 healthy young adults (22 women, mean age 28) spent three nights in a laboratory, including nights with disrupted sleep. Four wearable and three contactless devices were compared with polysomnography. Sensitivity—the share of sleep correctly identified—was at least 0.93 for all devices. Specificity—the share of wakefulness correctly identified—was only 0.18–0.54. The authors called sleep-stage comparisons ambiguous; devices performed worse on nights with poor and fragmented sleep. They also noted that results need to be checked in other groups of people 1.

A large study by Lee and colleagues included 75 people from a hospital and sleep clinic in Korea and 11 devices of three types. Agreement on sleep stages varied considerably by device: the agreement score (macro F1, where 1 means a perfect match) ranged from 0.26 for the worst to 0.69 for the best. Wearables systematically made errors in sleep efficiency (the share of time in bed spent asleep), while devices placed near the bed made errors in sleep-onset time. Results depended on body-mass index, sleep efficiency, and the apnoea–hypopnoea index; differences between men and women were small 2.

A 2024 Sleep Research Society review summarizes that consumer devices assess sleep better than traditional actigraphy, but have limitations, especially misclassifying wakefulness during the sleep period. Their performance in people with certain characteristics is also unclear: in the authors’ assessment, skin color or obesity may affect sensor performance 3.

Table: what can you trust?

Measure How much to trust it How to use it
Total sleep duration In a lab study of healthy young adults, sleep was reliably detected while time in bed was set in advance 1; some devices overestimated duration Look at the weekly average, not one night
Nighttime awakenings Less reliable: specificity was 0.18–0.54, and wakefulness was often counted as sleep Do not count each awakening separately
Deep and REM sleep Agreement across all stages (macro F1) ranged from 0.26 to 0.69 depending on device 2; some devices in Chinoy’s study overestimated deep sleep and underestimated REM Do not make decisions based on one night’s number
Overall “sleep score” Manufacturer’s formula; the sources cited here do not compare these scores with a lab measure Do not compare across devices or apps
Breathing disorders or diagnosis The American Academy of Sleep Medicine says consumer devices should not be used to diagnose or treat sleep disorders 4 If you suspect sleep apnoea, see a doctor rather than buying another wearable

Orthosomnia: when a tracker gets in the way of sleep

A clinical report by Baron and colleagues describes patients who sought treatment for self-diagnosed “sleep deprivation” or insomnia based on light or restless sleep shown on tracker charts. Chasing a perfect sleep number can become perfectionistic, and patients often trust tracker data more than their own feelings or validated methods such as polysomnography and actigraphy 5. These are descriptive observations; prevalence was not assessed.

Signs it may be time to ease up:

  • You worry about a “bad score” before you feel unwell.
  • You try to “get more deep sleep” and worry that you have too little.
  • The number on screen feels more convincing than how you feel in the morning.
  • In the evening, you think about what score you will get.

If you recognize yourself in these points, hide the numbers for a week and pay attention to how you feel during the day. If your sleep is still genuinely poor, talk to a doctor.

Five rules for reading the data

The rules below are the author’s takeaways from these comparisons; the studies themselves do not give this advice:

  1. Use an average over 1–2 weeks, not a single night.
  2. Compare the numbers with how you feel during the day: if you have enough energy, “poor” stages are not a reason to worry.
  3. Do not change your routine because of one night.
  4. Do not compare numbers across devices: Lee’s study found substantial differences 2.
  5. For regularity, use your recorded bedtime and wake time (from a log and alarm); use the tracker as a guide to total sleep duration. How many hours you need is covered in “How Much Sleep Do Adults Need? Recommendations and Your Own Baseline”.

Example of reading a week (illustrative numbers). Your recorded bedtimes: 23:10, 23:40, 00:20, 23:30, 00:50, 01:30, 00:10; tracker-recorded sleep duration: 6.8, 7.2, 6.4, 7.0, 7.9, 8.4, 7.3 hours. Average duration is 51.0 / 7 = about 7.3 hours, which looks fine. But bedtime varies from 23:10 to 01:30, a spread of 2 hours 20 minutes. That number comes from your own log; you do not need sleep stages to see it. You can ignore the stage breakdown for all seven nights.

If your wearable sends data to Apple Health or Health Connect (Nuteva reads sleep, steps and heart rate from both; see “Apple Health: Where the Data Comes From and How to Avoid Double Counting” and “Health Connect: What It Is and Why Steps May Not Transfer”), you can place the week of sleep next to workouts and food logs in Nuteva and see whether short nights coincide with hard days. Accuracy of wearable calorie estimates is covered in “How a Fitness Tracker Counts Calories and What to Trust”.

When a tracker cannot replace a doctor

The NHS lists the main signs of sleep apnoea as breathing stopping and starting during sleep, choking, snorting, or gasping during sleep, and persistent severe daytime tiredness. It advises seeing a doctor if you have any of these signs 6. The NHS defines insomnia lasting three months or more as long-term and advises seeing a doctor if changing habits has not helped, sleep problems have lasted for months, or insomnia makes daily life hard to manage 7. The AASM position statement allows tracker data to be used as additional information at an appointment alongside appropriate clinical assessment 4.

Questions for a doctor:

  • Can sleep charts from my wearable be useful, and which data should I share?
  • Do I need a sleep study if I snore and have pauses in breathing?
  • What steps should I take if insomnia has lasted more than three months?

Choose a week and write down two numbers: when you went to bed and got up each day (from your log or alarm), plus total sleep duration from the tracker. The difference between your earliest and latest bedtime is something concrete to work on.

Sources

  1. Chinoy E. D. et al., Performance of seven consumer sleep-tracking devices compared with polysomnography, Sleep, 2021. 34 healthy young adults (mean age 28), three nights in a laboratory, four wearable and three contactless devices; results may differ for other groups and models.
  2. Lee T. et al., Accuracy of 11 wearable, nearable, and airable consumer sleep trackers: prospective multicenter validation study, JMIR Mhealth Uhealth, 2023. 75 participants at two centers in Korea, 11 commercial devices of three types compared with polysomnography; some authors were affiliated with the developer of one app, and testing took place in a hospital setting.
  3. de Zambotti M. et al., State of the science and recommendations for using wearable technology in sleep and circadian research, Sleep, 2024. Sleep Research Society-commissioned review of capabilities and limitations of wearable sleep trackers; review for researchers.
  4. Khosla S. et al., Consumer sleep technology: an American Academy of Sleep Medicine position statement, J Clin Sleep Med, 2018. AASM position on consumer sleep technology; US document from 2018.
  5. Baron K. G. et al., Orthosomnia: are some patients taking the quantified self too far?, J Clin Sleep Med, 2017. Clinical report on patients distressed by tracker data; descriptive work without a prevalence estimate.
  6. NHS: Sleep apnoea. Main symptoms and when to see a doctor.
  7. NHS: Insomnia. Definition of long-term insomnia and when to see a doctor.

Nuteva features

Read next