For education. Use a qualified healthcare professional for diagnosis and treatment decisions. How we use sources.
HOMA-IR is calculated as fasting glucose (mmol/L) multiplied by fasting insulin (µU/mL), divided by 22.5 1. The arithmetic is simple, but there is no universal cutoff between “normal” and “not normal”: the Oxford researchers who developed the calculation model state that values depend on assay methods and there are no defined cutoffs 1. Diabetes and prediabetes are diagnosed using glucose and HbA1c; the index is not part of the ADA diagnostic criteria table 2.
Where the index came from and what it estimates
In 1985, Matthews and colleagues proposed a model that estimates insulin resistance and pancreatic beta-cell function from fasting glucose and insulin. The idea is that baseline glucose and insulin are determined by their interaction in a feedback loop, so their combination can estimate the contribution of reduced insulin sensitivity and beta-cell dysfunction. In plain language, if a lot of insulin is needed to keep glucose at a given level, the calculated resistance is higher. In the original study, the estimate correlated with the reference clamp method (coefficient 0.88), but the authors themselves noted low precision as a limitation: the coefficient of variation for the estimate was 31% 3.
Since then, the method has been widely used in clinical and epidemiological research. A 2004 review co-authored by Matthews cautioned that input data must be reliable and the result interpreted carefully 4. The Oxford center that maintains the method separately notes that the calculator is for professionals and should be used by patients only with their treating clinician 1.
How to calculate it: formula and examples
If insulin is reported in µU/mL (sometimes mU/L) and glucose in mmol/L, divide by 22.5. If glucose is in mg/dL, divide the product by 405; a study using this version writes it this way 5. Both versions produce the same result because 18 × 22.5 = 405.
Insulin reported in pmol/L must first be converted. In the same study, values of 12.9 µU/mL and 89.6 pmol/L appear side by side, so 1 µU/mL is about 6.9 pmol/L. The literature rounds the conversion factor differently (the same source also gives 1 pmol/L = 0.14 µU/mL), so check the units on your report 5. Example: insulin of 70 pmol/L is about 10 µU/mL.
| Glucose, mmol/L | Insulin, µU/mL | Calculation | HOMA-IR |
|---|---|---|---|
| 5.2 | 10 | 52 / 22.5 | 2.31 |
| 5.0 | 14 | 70 / 22.5 | 3.11 |
| 5.0 | 8 | 40 / 22.5 | 1.78 |
| 5.0 | 12 | 60 / 22.5 | 2.67 |
| 4.6 | 11.3 | 52 / 22.5 | 2.31 |
| 5.8 | 9 | 52.2 / 22.5 | 2.32 |
Rows 1, 5 and 6 show why the index can be confusing: a value around 2.3 can result from low glucose with high insulin or higher glucose with lower insulin. Different states give the same number, so both underlying values matter.
There is a refined HOMA2 model. It is not a simple formula; a computer program solves it, and it expresses beta-cell function and insulin sensitivity as percentages of a normal reference population 6. The simple formula in the table above is only a linear approximation and can differ substantially from the program’s result, especially at extreme values 1. Therefore, HOMA2 values should not be compared with the classic index.
Why there is no universal cutoff
The first reason is noted above: values depend on the methods used to measure glucose and insulin 1. The repeatability study authors add that insulin assays are poorly standardized, whereas lipid assays are well standardized 5. So a result from one laboratory cannot be directly compared with a cutoff from a publication that used another method.
The second reason is that the marker itself varies. In the ARIC study, 102 adults aged 68–88 without diabetes (average age 76, 68% women) had blood drawn twice, an average of 46 days apart (range 28–102). Median HOMA-IR was about 2.2, with a range from 0.9 (5th percentile) to 5.6 (95th). The within-person coefficient of variation for HOMA-IR was 30.4%, meaning a single measurement differed from a person’s average by about one-third; it was 28.8% for insulin and 5.6% for glucose. The authors estimated the minimum change distinguishable from measurement error at 2.3 units. For one in twenty participants, the difference between visits was 2.5 or more 5. The sample was small and older, and results could differ in younger people, but the scale is informative.
Now return to the table. With glucose of 5.0, insulin of 8 and 12 µU/mL gives 1.78 and 2.67. The 0.89 difference is far from the 2.3 minimum detectable change, and with that much variability the same person could fall on either side of any cutoff between 1.78 and 2.67 without changing their lifestyle. The same caveat applies: the variability was measured in older adults.
What affects the result and what to check before comparing two tests
Insulin is tested fasting; MedlinePlus says 8–12 hours, but the laboratory sets the exact instruction. It also says that if you take biotin (vitamin B7), ask whether to stop it at least a day before the test; insulin medications may affect accuracy because some people develop antibodies that interfere with measurement 7. A doctor decides what to do; do not stop medication on your own.
Glucose also depends on the circumstances: according to the ADA, recent physical activity, illness and acute stress can affect glucose concentration, and a sample that is not processed promptly may have a falsely low result because of glycolysis 2. Russian guidelines list medications that raise blood glucose: glucocorticoids, thyroid hormones, thiazide diuretics and beta blockers 8. Oxford researchers note another nuance: the calculator is designed for plasma; insulin values in serum may be lower 1.
Before comparing two results, check:
- the same laboratory and method;
- the same insulin units (µU/mL or pmol/L) and glucose units (mmol/L or mg/dL);
- how many hours you had fasted, and whether this is recorded on the report;
- whether you were ill, under severe stress or did unusual exercise around the test;
- which medications and supplements you took (biotin, glucocorticoids, insulin medications);
- whether the sample was plasma or serum, if noted.
If you store reports in Nuteva lab history, compare the index only across results from one laboratory and with the same insulin units. You can keep the same table in a note or notebook.
Where the index is useful and where it falls short
The ADA diagnoses diabetes using HbA1c, fasting glucose, glucose two hours after 75 g of glucose, or random glucose with symptoms. The WHO’s 2006 document also bases its criteria on glucose: fasting and two-hour 2, 9. Russian Ministry of Health clinical guidelines for “Type 2 diabetes in adults” state that diagnosis is made only from blood glucose or HbA1c 8. MedlinePlus adds that insulin tests are not usually used to diagnose diabetes, although doctors may combine them with glucose and HbA1c when assessing insulin resistance 7.
In practice, a doctor may consider HOMA-IR as additional information alongside other markers, but one number does not diagnose or rule out anything. See “Glucose and HbA1c: what is the difference?” for how glucose and HbA1c differ. For insulin resistance as a concept and the markers discussed around it, see “Insulin resistance”. For prediabetes criteria, see “Prediabetes”.
Questions for your doctor
- Why were insulin and HOMA-IR ordered, and would the result change the plan?
- Which markers matter more for assessing risk: glucose, HbA1c, lipids or blood pressure?
- Do I need a repeat test, at the same laboratory and under the same conditions?
- Could medications or supplements, such as biotin or glucocorticoids, have affected the result?
- Do I need an oral glucose tolerance test or repeat HbA1c to clarify the picture?
Bring the report showing both values, units and fasting time. Without them, the index alone says little.
Sources
- University of Oxford, Diabetes Trials Unit: HOMA Calculator FAQ. HOMA1 formula, no cutoffs, plasma-versus-serum difference, calculator purpose; information from the method’s developers.
- PMC: Standards of Care in Diabetes—2026, Section 2 (ADA). Diagnostic and prediabetes criteria, factors affecting glucose; US guidelines.
- PubMed: Matthews et al., Diabetologia, 1985. Original model paper, correlation with clamp and coefficient of variation for the estimate.
- PubMed: Wallace et al., Diabetes Care, 2004. Review of the method’s use and conditions for appropriate application.
- PMC: Poon et al., J Clin Endocrinol Metab, 2018. HOMA-IR repeatability among 102 adults aged 68–88 without diabetes (US ARIC study), average 46-day interval, units and conversion factors.
- University of Oxford, Diabetes Trials Unit: HOMA Calculator. What HOMA2 estimates and how its results are expressed.
- MedlinePlus: Insulin in Blood Test. Preparation, effects of biotin and insulin medication, role of test in diagnosis; US reference.
- Russian Ministry of Health: clinical guideline “Type 2 diabetes in adults” (ID 290_2, 2022). Diagnostic criteria and medications that raise blood glucose. 2022 edition (checked 26 Nov 2026): check cr.minzdrav.gov.ru for a newer edition.
- WHO: Definition and diagnosis of diabetes mellitus and intermediate hyperglycaemia (2006). Criteria based on fasting and two-hour glucose; 2006 document.
